SimpleSwitch 240CT comes with Clamp Style CT's

$1,097.00

Unit Price: $1,097.00

How it Works Summary:

  • The simpleSwitch240 CT will measure the power load on the whole panel. It will turn off the simpleSwitch 240 CT connected to an appliance/device if the whole panel load exceeds the 80% threshold (i.e. shed power load connected to an appliance).
  • In this application, the simpleSwitch240 CT external Current Transformers (CTs) are connected to the main service line input wires inside the electrical panel. This is to monitor if power drawn on the whole panel exceeds thresholds.
  • The simpleSwitch 240CT will measure the power load on the whole panel using external clamp style current transformers (CTs). When whole panel load exceeds 80% threshold simpleSwitch 240CT will temporarily switch off the power load of the appliance/device connected to the simpleSwitch240 CT (“Shed the Power”).
SKU: ss240ct-clampct Category:

Specification

Specifications:
Model
simpleSwitch 240CT™
Weight (pounds)
5 lbs.
Dimensions (W x H x L in)
7.58 x 7.58 x 4.90 in
Power Connection (Volts/Amps) 50/60Hz
120-208/240VAC 60Amp Breaker Max. (3PH Min 206VAC)
Full Load Rating - Continuous Use
Suggested Appliance Amperage
50 Amps
≤48 Amps
Overcurrent Protection on Internal Contactors
Set by manufacturer at 50Amps on Secondary Output Only
Maximum Breaker Size
60Amps
Contactor Type
Latching
Enclosure Rating NEMA
Type 1, 2, 3R, 4, 4X, 6, 6P, 12, 13
Mounting Environment / Orientation
Indoors or Outdoors / Horizontal or Vertical or Inverted
Ambient Temperature Degrees Celsius
Operating -40 to 70 °C
Conductor Metal Type to be Connected to simpleSwitch
Copper conductor wire to simpleSwitch terminal ports only.
(No Aluminum cable is to connect directly to simpleSwitch)
Delay Time
A delay of five (5) minutes to restore power to the switched appliance after Current Transformers (CTs) have measured power usage under set threshold values
Fail-Safe
Contactors to Secondary Output open if there is a malfunction of power or internal board, disconnecting the supply of power to Secondary Output
Conductor Fill in Enclosure
Maximum number of conductors 9.
Not to be used as junction box for other uses
Horsepower Rating
5 HP
Standard(s) for Safety:
UL 916, Energy Management Equipment
CSA C22.2 No. 205-17 Signal Equipment
Testing
UL Certificate of Compliance E510161 US/CAN LISTED

 

Device Functionality:

  1. simpleSwitch 240CT works by constantly measuring the power load, created from electrical devices’ energy consumption, on the whole panel (or subpanel) using external current transformers (CTs).
  2. When electrical load exceeds a set threshold of 80%, simpleSwitch 240CT will switch off the power load of the appliance/device connected to the simpleSwitch 240CT (“Shed the Power”).
  3. Power is restored to the appliance/device connected to the simpleSwitch 240CT after power load remains under set threshold values for 15 minutes.
A diagram of the model 2 4 0 ct is shown.

Wiring Diagram